Sick THTS Hygienic Resistance Thermometer

Sick THTS Hygienic Resistance Thermometer

Sick's THTS temperature sensor is a compact PT100 resistance thermometer suitable for hygienic applications within the food and beverage, cosmestics and pharamceutical industries.

The THTS is constructed of stainless steel and has a crevice free design of the wetted parts to ensure conformity to hygienic standards and is suitable for CIP and SIP processes.

A wide range of process connections which are welded gap-free to the connection housing are available as are multiple insertion lengths to allow for universal use.

In addition to a direct electrical connection to the PT100 element, an integrated transmitter is available with a 4mA to 20mA output signal.

Sick THTS Hygienic Resistance Thermometer - Features & Benefits

  • Pt100 element, accuracy class A (IEC 60751)
  • Measuring ranges -50°C to +150°C and -50°C to +250°C
  • Wetted parts: Corrosion-resistant stainless steel 316L/1.4435, Ra ≤ 0.8 µm
  • Various hygienic process connections and insertion lengths
  • Pt100 (4-wire) or 4 mA to 20 mA (2-wire)
  • Round connector M12 x 1
  • Convenient system integration – installation in narrow installation space possible through compact dimensions
  • Safe, hygienic operation due to wetted parts made from high-grade stainless steel, hygienically-graded surface finish and a gap- and crevice-free design
  • Rugged: Connection housing is easily cleaned and splash proof
  • Quick and safe installation
  • Very good long-term stability, accuracy and linearity
  • Quick response time
  • Optimal solutions for individual requirements due to versatile configurability
Sick THTS Hygienic Resistance Thermometer - Technical Specification
Measuring Ranges

-50ºC to +150ºC

-50ºC to +250ºC

Sensor Element PT100
Signal Outputs and Maximum Ohmic Load Ra Pt100, 4-wire
4 mA to 20 mA, 2-wire (RA ≤ (L+ –10 V) / 0.023 A [Ohm])
Accuracy of Sensor Element Class A according to IEC 60751
Accuracy of Optional Transmitter ≤ ± 0.2 % of span
Linearity of Optional Transmitter ≤ ± 0.1 % of span
Response Time Response time t50 ≤ 3.3 s
Response time t90 ≤ 9.7 s
Insertion Lengths / Diameter of Probe 25 mm / 6 mm
50 mm / 6 mm
75 mm / 6 mm
100 mm / 6 mm
150 mm / 6 mm
200 mm / 6 mm
Wetted Parts Stainless steel 1.4435 (316L) Ra ≤ 0.8 µm
Pressure Resistance 16 bar with clamp connections according to DIN 32676, ISO 2852 and tri-clamp
40 bar with conical coupling (DIN 11851) DN 20, DN 25, DN 32 and DN 40 with union nut
25 bar with conical coupling (DIN 11851) DN 50 with union nut
25 bar with Varivent connector form B, DN 10, DN 15
25 bar with Varivent connector form F
16 bar with Varivent connector form N
Housing Material Stainless steel 1.4571 (316Ti)
Enclosure Rating IP68 and IP69K
Electrical Connection Round connector M12 x 1, 4-pin
Measuring Current 0.3 mA to 1 mA, for variant with output signal Pt100
Supply Voltage 10 V DC to 35 V DC for variant with transmitter 4 mA to 20 mA
Maximum Current Consumption Ca. 30 mA for variant with transmitter 4 mA to 20 mA
Electrical Safety Protection class: III
Dielectric strength: 500 V AC
Reverse polarity protection of variant with transmitter 4 mA to 20 mA: L+ towards M
CE Conformity 2004/108/EC, EN 61326-2-3
RoHS Certificate Yes
Initialisation Time < 10ms

 