Sick LFV330 Vibrating Tuning Fork - Point Level Sensor

Sick LFV330 Vibrating Tuning Fork - Point Level Sensor

Sick's LFV330 range of tuning forks are level sensors which are universal vibrating level sensors which detect predefined filling heights in liquid systems with millimetre accuracy even under difficult operating conditions.

Regardless of maximum fill amounts in containers as full messages to prevent overfilling, empty messages to prevent dry running or switching signal for refilling or as idle message for pump protection, the LFV330 tuning forks run independently of the liquid and are wear-free and maintenance-free.

A wide selection of flange, threads and hygienic connections allow customer-specific solutions including hygienic applications and can be cleaned using SIP and CIP processes.

There are also variants for use in potentially explosive atmospheres, to prevent overfilling (in compliance with WHG), and with marine certification (GL).

The LFV330 offers tube-extended versions for vertical mounting to bridge switching distances up to 6m.

Sick LFV330 Vibrating Tuning Fork - Point Level Sensor - Features & Benefits

  • Universal technology works in all kind of liquids
  • Commissioning without filling
  • Process temperature up to 250 °C
  • Immune to deposit formation
  • Very high repeatability
  • Aseptic versions according to EHEDG and FDA available
  • CIP and SIP resistant
  • ATEX certification available
  • Polished surface
  • Universal technology works in all kinds of liquids
  • Maintenance-free limit switch, reduced maintenance costs
  • No calibration required, reduce costs
  • Low installation cost
  • Flexible level switch
  • Fast commissioning saves time
  • Sensor test in situ
  • Several housing materials and electrical outputs available
  • Tube extension up to 6m
Sick LFV330 Vibrating Tuning Fork - Point Level Sensor - Technical Specification
Medium Fluids
Measurement Switch
Probe Length 80mm to 6,000mm
Process Pressure - 1 bar to 64 bar
Process Temperature

-50ºC to +150ºC

-50ºC to +250ºC

Fill Material Density 0.5 g/cm³ to 2.5 g/cm³
Accuracy of Sensor Element ± 2mm
Repeatability ≤ 1mm
Viscosity 0.1 mPas to 10,000 mPas
Response Time 500ms
Wetted Parts Stainless steel 1.4404 (optional Ra ≤ 0.8µm) 
Housing Material

Plastic

Aluminium

Stainless Steel (casted) 316L

Stainless Steel (electropolished)

Sensor Material Stainless steel 316L