Nelson QLT Heat Tracing Cable

Heat Tracing Cable

Nelson QLT

ATEX & IECEX Heat Tracing CableNelson QLT heat tracing cable is suitable for process temperature maintenance up to 121ºC (250ºF) and can be used within potentially explosive zone 1 & zone 2 hazardous areas as it is ATEX & IECEx certified.

Pictured: Nelson QLT Heat Tracing Cable - Suitable for Hazardous Area Process Temperature Maintenance

Nelson QLT Heat Tracing Cable

QLT heat tracing cables are self-regulating and adjust their heat output in response to changes within the ambient conditions. This ensures that the cable will never overheat or waste energy.

The QLT heat tracing cables are available with heat outputs of 10, 15 and 20 watts per foot (at 10ºC / 50ºF) and for both 120V and 240V power supplies.

Nelson QLT Heat Tracing Cable - Product Range
Part Ref

Supply

Voltage

Watts / Ft

T

Rating

QLT10 120VAC 10 watts per ft T3
QLT210 240VAC 10 watts per ft T3
QLT15 120VAC 15 watts per ft T3
QLT215 240VAC 15 watts per ft T3
QLT20 120VAC 20 watts per ft T3
QLT220 240VAC 20 watts per ft T3

Pictured: Nelson QLT Heat Tracing Cable Power Output Graph

Nelson QLT Heat Tracing Cable Power Output Graph

Nelson QLT Heat Tracing Cable - Circuit Breaker Selection
Supply Voltage

Part Ref

Max Total Length

vs Circuit Breaker Size

15A 20A 30A
120VAC QLT10 115ft 150ft 190ft
QLT15 80ft 110ft 135ft
QLT20 65ft 85ft 105ft
240VAC QLT210 225ft 300ft 375ft
QLT215 160ft 215ft 270ft
QLT220 125ft 170ft 210ft