Heat Tracing Cable
Nelson
CLT - 3, 5 & 8w/ft
Nelson CLT heat tracing cable and is ideal for providing frost protection to both plastic and metallic pipework. It can also be used for roof and gutter heating frost protection applications.
The heat tracing cable can be installed in both wet and dry environments with temperatures as low as -40ºC (-40ºF) and can be exposed to temperatures up to 85ºC (185ºF).
Pictured: Nelson CLT Heat Tracing Cable Characteristics
CLT heat tracing cables are self-regulating which ensures that the cable never overheats or wastes energy. They can be provided to provide power outputs of 3, 5 and 8 watts per ft at 10ºC (50ºF) with maximum circuit lengths of 533ft 240VAC and 221ft 120VAC.
Part Ref | Supply Voltage | Watts per Foot |
---|---|---|
CLT3 | 120VAC | 3 watts per ft |
CLT23 | 240VAC | 3 watts per ft |
CLT5 | 120VAC | 5 watts per ft |
CLT25 | 240VAC | 5 watts per ft |
CLT8 | 120VAC | 8 watts per ft |
CLT28 | 240VAC | 8 watts per ft |
Pictured: Nelson CLT Heat Tracing Cable Power Output Chart
Supply Voltage |
Part Ref |
Start Up Temperature |
Max Total Length vs Circuit Breaker Size |
||
---|---|---|---|---|---|
15A | 20A | 30A | |||
120VAC | CLT3 | 50ºF / 10ºC | 221ft | N/A | N/A |
0ºF / -18ºC | 208ft | 221ft | N/A | ||
-20ºF / -29ºC | 187ft | 221ft | N/A | ||
CLT5 | 50ºF / 10ºC | 178ft | N/A | N/A | |
0ºF / -18ºC | 150ft | 178ft | N/A | ||
-20ºF / -29ºC | 135ft | 178ft | N/A | ||
CLT8 | 50ºF / 10ºC | 142ft | N/A | N/A | |
0ºF / -18ºC | 105ft | 140ft | 142ft | ||
-20ºF / -29ºC | 95ft | 127ft | 142ft | ||
230VAC | CLT23 | 50ºF / 10ºC | 533ft | N/A | N/A |
0ºF / -18ºC | 416ft | 533ft | N/A | ||
-20ºF / -29ºC | 374ft | 499ft | 533ft | ||
CLT25 | 50ºF / 10ºC | 413ft | 458ft | N/A | |
0ºF / -18ºC | 299ft | 399ft | 458ft | ||
-20ºF / -29ºC | 269ft | 359ft | 458ft | ||
CLT28 | 50ºF / 10ºC | 289ft | 347ft | N/A | |
0ºF / -18ºC | 210ft | 280ft | 347ft | ||
-20ºF / -29ºC | 190ft | 253ft | 347ft |