Kamstrup Heat Meter - Multical 602

Kamstrup

Kamstrup Heat Meters

Kamstrup Multical 602

RHI MID Class 2 Heat Meters

 

Kamstrup’s Multical 602 is an all-purpose heat calculator for heat and cooling together with almost any kind of pulsed flow meters and with 2 or 4 wired temperature sensor pairs.

Kamstrup Multical 602 Heat Meter

When used together with Kamstrup’s Ultraflow 54 ultrasonic flow meter more advanced functions are available.

The Kamstrup Multical 602 is a compact heat meter which measures the exact consumption with a high level of accuracy.

The Kamstrup heat meter is maintenance-free and has a long lifetime with minimal yearly operating costs.

Kamstrup’s Multical 602 is used for heat, cooling and combined heat / cooling measurement in all water-based systems with temperatures from 2°C to 180°C for heat and 2°C to 50°C for cooling.

The Multical 602 is used as heat meter together with the Ultraflow 54 flow meter and two temperature sensors.

Flow sizes range from qp 0.6 m³/h to 1,000 m³/h. In cooling applications up to qp 100 m³/h the meter is connected to the Ultraflow 14 flow meter and temperature sensors, whereas the meter is used together with the Ultraflow 54 in cooling applications from qp 150 m³/h to qp 1,000 m³/h.

The heat calculator can be used with flow parts up to qp 3,000 m³/h.

Kamstrup Multical 602 Heat Meter

The Kamstrup Multical 602 is characterized by its complete range of communication modules and integral RTC (Real Time Clock), which make it easy to fit the meter into all applications independent of reading type.

The heat meter can be fitted with LON, SIOX, M-Bus, a data module and the new solutions Metasys N2 and Ethernet/IP for wired communication.

If the energy meter is to be integrated into a wireless network, you can select radio, Wireless M-Bus, Zigbee or one of Kamstrup‘s new modules: GSM/GPRS or High Power RadioRouter.

Kamstrup Multical 602 Heat Meter Technical Specification
Energy Units MWh, KWh, GJ, Gcal
Data Logger (Eeprom)

1392 hours, 460 days, 36 months, 15 years, 50 info codes

 

Optional data loggers with programmable interval

Data Communication KMP protocol with CRC16 used for optical communication and for top and base modules
Mains Supply 230 VAC +15/-30%, 50/60 Hz
24 VAC ±50%, 50/60 Hz
Environment Class Meets EN 1434 class A and C
Ambient Temperature 5 - 55ºC, non condensing, closed location (indoor installation)
Protection Class IP54
Storage Temperature -20ºC to 60ºC (drained flow meter)
Connection Cables 3.5mm to 6mm diameter
Supply Cable 5mm to 10mm diameter

Kamstrup’s range of heat meters are approved to EN 1434 and MID class 2 these products guarantee conformance to installation, operating monitoring and maintenance and also allows these to be utilised for the RHI scheme.

UK Time - GMT:

Kamstrup Heat Meter

Heat Tracing - Thorne & Derrick