HEWL EXHEAT Hazardous Area Water Line Heaters - ATEX Zone 1 & Zone 2

EXHEAT HEWL Hazardous Area Water Line Heaters - ATEX Zone 1 & Zone 2

ATEX Certified Zone 1 & Zone 2 Flameproof Line Heater for Water and Process Fluids

EXHEAT's HEWL range of hazardous area flameproof line heaters provide safe electrical heating for bulk liquid flow applications and all process fluids which are non corrosive to the materials the line heater is constructed from. HEWL line heaters are flameproof, suitable for Zone 1 & Zone 2 hazardous areas and are also available in a non-hazardous area variation.  

Typical applications include industrial washing and rinsing processes, engine jacket pre-heating, temperature maintenance of storage tanks and indirect heating of liquids.

The hazardous area flameproof line heater has individually replaceable Incoloy 825 sheathed elements and has a protected terminal enclosure certified weatherproof to IP55. HEWL line heaters have internal control thermostats and an over-temperature protection thermostat fitted as standard.

HEWL Hazardous Area Flameproof Line Heater Product Range
Part Number Loading (KW) Dimensions
HEWL15 15KW

Overall Length - 1495mm

Overall Width - 290mm

Overall Height - 526mm

HEWL18 18KW

Overall Length - 1495mm

Overall Width - 290mm

Overall Height - 526mm

HEWL24 24KW

Overall Length - 1805mm

Overall Width - 290mm

Overall Height - 526mm

HEWL30 30KW

Overall Length - 1805mm

Overall Width - 290mm

Overall Height - 526mm

HEWL45 45KW

Overall Length - 1895mm

Overall Width - 353mm

Overall Height - 575mm

HEWL60 60KW

Overall Length - 1895mm

Overall Width - 353mm

Overall Height - 575mm

HEWL75 75KW

Overall Length - 1895mm

Overall Width - 416mm

Overall Height - 628mm

HEWL90 90KW

Overall Length - 1895mm

Overall Width - 416mm

Overall Height - 628mm

HEWL105 105KW

Overall Length - 1895mm

Overall Width - 416mm

Overall Height - 628mm

HEWL120 120KW

Overall Length - 1895mm

Overall Width -  416mm

Overall Height - 628mm

 

HEWL Hazardous Area Flameproof Line Heater - EXHEAT Technical Specification
Enclosure Weatherproof protection to IP55
Heating Element Incoloy 825 sheathed rod type
Working Pressure Up to 5 bar.g
Design Code Sound Engineering Practice (SEP)
Vessel Carbon Steel
Insulation Mineral Wool
Cladding Stucco Aluminium
Supply Voltage Standard supplies up to 690V

 

HEWL EXHEAT Hazardous Area Water Line Heaters - ATEX Zone 1 & Zone 2
UK Time - GMT:

HEWL EXHEAT Hazardous Area Water Line Heaters - ATEX Zone 1 & Zone 2
HEWL EXHEAT Hazardous Area Water Line Heaters - ATEX Zone 1 & Zone 2

Heat Tracing - Thorne & Derrick