FLR EXHEAT Flameproof Hazardous Area Radiators - ATEX & GOST-R Zone 1 & Zone 2

EXHEAT FLR Flameproof Hazardous Area Radiators - ATEX & GOST-R Zone 1 & Zone 2

ATEX & GOST-R Zone 1 & Zone 2 Radiator

EXHEAT's FLR range of flameproof ATEX & GOST-R liquid filled radiators are an ideal heating solution for Zone 1 & Zone 2 hazardous areas where airborne dust particles are of a particular concern.

The FLR range of radiators are suitable for ambient temperatures from -20ºC to 40ºC. The radiators have a surface temperature limited to meet EN563 safety requirements and are certified weatherproof to IP66. Additionally a manual reset over temperature cut-out is fitted to ensure the radiators surface temperature does not exceed 80ºC.

FLR radiators are filled with a water/glycol mix and are floor mounted using welded on feet and wall retention brackets.

Typical Applications for FLR Flameproof Hazardous Area Radiators

  • Ammunition Depots
  • Explosive Stores
  • Chemical Plant Warehouses
  • Firework Factories
  • Sugar Refineries
  • Laboratories
FLR Hazardous Area Radiator Product Range
Part Number Power Output (KW) Dimensions Weight
FLR1 1KW

Length - 540mm

Width - 160mm

Height - 835mm

47kg
FLR2 2KW

Length - 1080mm

Width - 160mm

Height - 835mm

94kg
FLR3 3KW

Length - 1620mm

Width - 160mm

Height - 835mm

140kg

FLR Hazardous Area Radiator - EXHEAT Technical Specification
Enclosure Lightweight cast aluminium finished in orange
Radiator Lightweight, pressed steel with white powder coated finish
Heating Element Rod type, comprising of high quality 80/20 Nickel Chromium resistance wire, compacted in Magnesium Oxide insulating powder and encased in corrosion resistant Incoloy 825 metal sheath
Controls

Preset radiator surface temperature control thermostat and manual reset, safety, temperature limiter.

 

Optional externally adjustable control thermostat

Mounting Floor standing, with welded-on feed and wall retention brackets
Supply Voltage Standard 240V single phase. Other single phase supplies available on request.
Certification

ATEX certified EX II 2 G/D

EX'd' IIC T6 Ex tD A21 IP6X T85ºC

EN60079-0, EN60079-1, EN61241-1

GOST-R (contact T&D for further information)

 