Isopad's FIDR-SRB drum heaters provide medium flow and process temperature for Zone 1 & Zone 2 hazardous areas.
The Isopad FIDR-SRB drum heater provides heat to the enclosed drum via a self regulating trace heating cable embedded within a solid metal housing to ensure the maximum in safety at operating conditions.
Isopad FIDR-SRB drum heaters include a mechanical thermostat which regulates the operating temperature. A lid is included with the FIDR-SR as standard however an optional insulated lid is recommended to prevent heat loss through the top of the container.
The Isopad FIDR-SRB drum heater also comes with conductive castors for easy transportation.
Part Number | Certification | Height | Inner Diameter | Outer Diameter | Nominal Power & Voltage | Weight |
---|---|---|---|---|---|---|
FIDR-SRB | ATEX & IECEx T6 | 990mm | 650mm | 770mm | 1810W, 230V | 60kg |
Heater Construction | Type - Self-regulating heating cable
Carrier & Outer Protection - Sheet steel Thermal Insulation Material - Glass-fibre, 50mm thickPaint - Matt black heat resistant and structured blue paint Fixation & Closure Type - Quick-snap fastener |
---|---|
Connection | Junction Box Type - STAHL Series 8118
Ingress Protection - IP66 Maximum Ambient Temperature - -50ºC to +55ºC Maximum Operating Temperate - 180ºCMaximum Connecting Cross Section - 4mm² Terminals - 8 Glands - 4 x M25Housing Material - Polyester glass-fibre reinforced Connection Lead - 2m Silicone insulated, 4mm² cross section |
Temperature Control | Thermostat Type - RAYSTAT-EX-02
Sensor Type - Capillary tube Controller Range: -4ºC to +163ºCMaximum Ambient Temperature - -40ºC to +60ºC Ingress Protection - IP65 Housing Material - Aluminium |
Technical Data | Frequency - 50-60 Hz
Maximum Operating Voltage - 277VAC Single Phase Maximum Operating Temperature - 65ºC to 120ºC (depending on heating cable type and temperature class) |
Certifications | System approval by Baseefa
ATEX & IECEx Certified EX II 2 G / D Ex de IIC T2 to T6Ex tD A21 IP65 T80ºC to T240ºC EN & IEC StandardSuitable for Zone 1 & Zone 2 (Gas) and Zone 21 & Zone 22 (Dust) Electrical Protection Class I Ambient Temperature Range - -40ºC to +50ºC |