FCR EXHEAT Hazardous Area Convector Heaters - ATEX, IECEx & GOST-R Zone 1 & Zone 2

EXHEAT FCR Hazardous Area Convector Heaters - ATEX, IECEx & GOST-R Zone 1 & Zone 2

ATEX, IECEx & GOST-R Zone 1 & Zone 2 Convector Heater for Space Heating in Work or Storage Areas

EXHEAT's FCR range of hazardous area Convector Heaters can provide space heating for work or storage areas that are located within Zone 1 & Zone 2 hazardous areas where the flammable atmosphere is a group IIA, IIB or IIC gas. Typical applications include battery stores, fuel servicing areas, chemical plants, aircraft hangers and offshore or gas installations.

FCR hazardous area convector heaters are designed with a sloped top to prevent objects being placed on top of the heater and can be floor or wall mounted. The FCR range of heaters are suitable for ambient temperatures of -40ºC to 40ºC and can be controlled by an optional built-in thermostat or a remote thermostat.

FCR Hazardous Area Convector Heater Product Range
Part Number Power Output (KW) Supply Voltage Dimensions Weight (kg)
FCR 1 1KW 240V

Length - 1240mm

Width - 165mm

Height - 375mm

17kg
FCR 1/110 1KW 110V

Length - 1240mm

Width - 165mm

Height - 375mm

17kg
FCR 2 2KW 240V

Length - 1240mm

Width - 165mm

Height - 375mm

32kg
FCR 2/110 2KW 110V

Length - 1240mm

Width - 165mm

Height - 375mm

32kg
FCR 3 3KW 240V

Length - 1750mm

Width - 165mm

Height - 375mm

47kg
FCR 3/415 3KW 415V / 3 Phase

Length - 1750mm

Width - 165mm

Height - 375mm

47kg

FCR Hazardous Area Convector Heater - EXHEAT Technical Specification
Enclosure Heavy duty folded steel
Heating Elements Individually replaceable, finned heating elements, comprising high quality 80/20 nichrome resistance wire, compacted in Magnesium Oxide insulating powder and encased in a stainless steel sheath
Finish Grey gloss, epoxy powder coated
Controls If required, the heaters can be controlled via an optional built-in control thermostat or via an remote mounted EXHEAT thermostat
Mounting Wall or floor mounting via brackets/feet supplied
Supply Voltage Standard 110V or 240V single phase and for the FCR3 only 415V 3 phase (other supplies by special order)
Certification

ATEX certified Ex II 2 G

IECEx & ATEX certified 'e' IIC T2 to T4

IEC/EN60079-0 & IEC/EN60079-7

GOST-R (contact T&D for further information)

 

FCR EXHEAT Hazardous Area Convector Heaters - ATEX, IECEx & GOST-R Zone 1 & Zone 2
UK Time - GMT:

FCR EXHEAT Hazardous Area Convector Heaters - ATEX, IECEx & GOST-R Zone 1 & Zone 2
FCR EXHEAT Hazardous Area Convector Heaters - ATEX, IECEx & GOST-R Zone 1 & Zone 2

Heat Tracing - Thorne & Derrick