Ashcroft Instruments 5509 differential pressure gauge comes standard with 316 SS wetted parts and has a rugged gauge with an external zero adjust feature as standard.
Model Number | 5509 |
---|---|
Accuracy | +/-2.5% full scale |
Ranges | 0-10 IWD (inches of water differential) to 400 psid |
Static Pressure |
From 10 IWD to 3 psi - static pressure 145 psi 5 psi and above - static pressure 360 psi |
Dial Size |
4" or 6" Zero adjust at top of case |
Case Material | 304 stainless steel open case (solid front optional) |
Ring | Bayonet ring |
Window | Shatterproof glass |
Dial | Aluminium, white background, black figures and intervals |
Pointer | Black painted alumnium with external adjust feature standard (to 25% of range) |
Ingress Protection |
IP54 (Dry) IP65 (Liquid Filled) IP65 Optional (Dry Case XLJ) |
Diaphragm Material |
316 stainless steel for ranges 10 psi and below. High strength cobald alloy (Duratherm 600) for ranges 15 psi and above |
Housing Material | 316 Stainless steel with a Vitron 0-ring |
Mounting | Stem, wall or pipe |
Connection Size | 0.25" or 0.5" NPT |
Connection Location | Lower |
Optional Features | |
Glycerin Fill | L - Standard |
Silicone Fill | XGV - Optional |
Weatherproof / Hermetically Sealed Case (IP65) | XLJ |
Wall Mounting Bracket | XFW |
316 SS Case And Ring | XYW |
Pipe Mounting Bracket | XTM |
3-way Manifold | X43 |
Polycarbonate Window | XPD |
Solid Front | S |
Calibration Chart | C4 |
Oxygen Cleaning | 6B |
Stainless Steel Tag-Wired | NH |
Stainless Steel Tag-Bonded | MN |
Electric Contacts |
Single Set Point - Close High Contact QH Open Low Contact QL Dual Set Point - High & Low Contact ED Double High Contact EE Double Low Contact EF
Electric contacts are available as an option on both dry and liquid filled gauges. |