Ashcroft Instruments 1001T XOR refrigeration pressure gauges are constructed to meet the unique requirements of the HVAC, automotive and refrigeration industries.
Ashcroft’s 1001T XOR pressure gauges are specifically designed for refrigerant recovery and recycling units and are tested for leaks as small as 2.8 x 10-4 cc per second to ensure superior integrity.
Optional connections eliminate potential leaks at threaded joints and also eliminate customer cost for extra fittings.
Ashcroft Instruments 1001T XOR Refrigeration Pressure Gauges – Features & Benefits
Product Specifications | |
---|---|
Ashcroft Model No | 1001T, XOR |
Size | 1001T 2.5", 3.5" |
Accuracy | 1% at zero, 2% three fourths of scale,
5% last fourth scale |
Case | Black steel with studs and U-clamp for panel mounting |
Ring | None |
Window | 1001T 0.25 turn threaded polycarbonate |
Dial | Available refrigerant scales R12, R22, R502, R134A, 410A |
Pointer | Black, aluminium |
Bourdon tube | Bronze |
Movement | Patented PowerFlex™ with polyester segment and FlutterGuard™:
slotted span screw for minor span adjustments |
Socket | Brass |
Restrictor | 0.013 orifice throttle plug |
Connection | 0.125 NPT back, 0.25 NPT back |
Ranges | 30 in. Hg vac./0/120 psi retard to
250 psi; 0-500 psi; 3o0 in Hg. vac./0/350 psi retard to500psi; 0-800 psi |
Operating temperature | -40°F to 150°F, -40°C to 65°C |
Options | Non standard ranges
Alternate refrigerant ranges SAE Flare, Solder bib and ferrule connectionsCustomized dials Front flange case design (2.5" only) |