Trace Heating - Industrial

Trace Heating - Industrial
Industrial Trace Heating Cables and Systems Overview

Typical Industrial Temperature Maintenance Trace Heating Applications
Temperature maintenance trace heating with precise temperature control : glucose, fuel oils, paints, fertilizers.

 

Medium temperature trace heating for steam cleanable applications : polymers, esters, heavy fuels, acids.

 

High temperature trace heating : heavy oils, asphalt, sulphur, bitumen.

Trace Heating : BSX™ Trace Heating Cable

Trace Heating : BSX™ Trace Heating Cable -
Trace Heating : BSX™ Trace Heating Cable
Self-Regulating Trace Heating Cable
BSX self-regulating trace heating cables are designed to provide freeze protection or process temperature maintenance to metallic and non-metallic piping, tanks, and equipment.
  
Operating Voltage: 230 VAC (110V)
Maximum Maintenance Temperature: 65°C
   
Trace Heating : BSX™ Trace Heating Cable

Trace Heating : HTSX Trace Heating Cable

Trace Heating : HTSX Trace Heating Cable -
Trace Heating : HTSX Trace Heating Cable

HTSX self-regulating trace heating cables are designed specifically for process temperature maintenance or freeze protection where high temperature exposure capability is required. HTSX trace heating cables withstand the temperature exposures associated with steam purging.
  
Operating Voltage: 230 VAC
Maximum Maintenance Temperature: 121°C
   

Trace Heating : HTSX Trace Heating Cable

Trace Heating : VSX Trace Heating Cable

Trace Heating : VSX Trace Heating Cable -
Trace Heating : VSX Trace Heating Cable

High performance VSX self-regulating trace heating cables are designed specifically for process temperature maintenance or freeze protection where high maintain temperatures or high temperature exposure is required.
  
Operating Voltage: 230 VAC
Maximum Maintenance Temperature: 149°C

Trace Heating : VSX Trace Heating Cable

Trace Heating : RSX Trace Heating Cable

Trace Heating : RSX Trace Heating Cable -
Trace Heating : RSX Trace Heating Cable

RSX self-regulating trace heating cables are designed for applications where the watt density requirements preclude the use of the standard range of BSX cables.
  
Operating Voltage: 230 VAC
Maximum Maintenance Temperature: 65°C

Trace Heating : RSX Trace Heating Cable

Trace Heating : HPT Trace Heating Cable

Trace Heating : HPT Trace Heating Cable -
Trace Heating : HPT Trace Heating Cable

Power-Limiting Trace heating Cables
High performance HPT power-limiting trace heating cables are designed specifically for process termperature maintenance or freeze protection where high maintain temperatures or high temperature exposure is required.
  
Operating Voltage: 230 VAC
Maximum Maintenance Temperature: 149°C

Trace Heating : HPT Trace Heating Cable

Trace Heating : TESH Trace Heating Cable

Trace Heating : TESH Trace Heating Cable -
Trace Heating : TESH Trace Heating Cable

Series Constant Watt Trace Heating Cable
TESH series resistance constant watt trace heating cables are used where circuit lengths exceed the limitations of parallel resistance heating cables. TESH withstands the temperature exposures associated with steam purging.
  
Operating Voltage: 750 Vac
Maximum Maintenance Temperature: 260°C



Trace Heating : TESH Trace Heating Cable

Trace Heating : MI Trace Heating Cable

Trace Heating : MI Trace Heating Cable -
Trace Heating : MI Trace Heating Cable

MIQ high performance mineral insulated trace heating cables are used extensively for high temperature maintenance, high temperature exposure and/or high watt density applications which exceed the limitations of thermoplastic insulated cables.
  
Operating Voltage: 230 VAC
Maximum Maintenance Temperature: 500°C

Trace Heating : MI Trace Heating Cable
Heat Tracing - Thorne & Derrick